  170 Ambassador Dr. Mississauga, Ontario L5T 2H9  -  Phone: 905-670-2380     Email: info@bellcombustion.com


40 & 45 kW SPECIFICATIONS
  • Quiet, powerful, liquid-cooled engine fueled by natural gas or LP.
  • A standard weather protective enclosure protects generator from harmful weather and also effectively reduces exterior noise levels. Includes key locks for security.
  • Built-in charger maintains battery at optimum performance level.
  • Automatic safety shutdowns protect engine and generator in event of low oil level or pressure, high temperature, low coolant level, overspeed and/or overcrank.
  • Automatic seven-day exerciser runs the system for fifteen minutes each week to maintain to running condition.
  • Standard 200-amp remote-mounted automatic transfer switch for fast and efficient unattended transfer to generator when utility source fails. Housed in a NEMA 3R outdoor rated enclosure.




Generator Set
Model 04992 04373
Rated Power (kW)* LP 40 / NG 37 LP 45 / NG 40
60 Hz Phase Single Single
Voltage 120/240V 120/240V
Amps @ 120/240V, Single Phase 60Hz LP 333.3 / 166.6
NG 308.3 / 154.2
LP 375 / 187.5
NG 333.3 / 166.6
Engine / Alternator RPM 1800 1800
Engine 3.9L V6 4.3L V6
Fuel Natural gas or LP gas Natural gas or LP gas
UL 2200 Listed Yes Yes
CSA Listed Yes Yes
Main Line Circuit Breaker 200 Amp 200 Amp
Dimensions (L" x W" x H") 76.1 x 33.5 x 42.2 94.37 x 37.99 x 45.67
Unit Wt. (lbs.)** 1400 2100
* Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.

** Includes Transfer Switch

Controls
Start / Stop Control Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection.
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 70 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 15 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
Starter Lockout Starter cannot re-engage until 5 seconds after engine has stopped
2 Amp Timed Trickle Battery Charger Standard
Auto Switch Utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / Test Start with starter control, unit stays on. If utility fails, transfer to load takes place