25 kW SPECIFICATIONS
  • Our quietest, liquid-cooled model.
  • Powerful, industrial engine fueled by natural gas or LP gas.
  • A sound attenuated enclosure protects generator from harmful weather and reduces exterior noise levels. Includes key locks for security.
  • Built-in charger maintains battery at optimum performance level.
  • Automatic safety shutdowns protect engine and generator in event of low oil pressure, high temperature, overspeed and/or overcrank.
  • Automatic seven-day exerciser runs the system for fifteen minutes each week to maintain top running condition.
  • Standard 200-amp remote-mounted automatic transfer switch for fast and efficient unattended transfer to generator when utility source fails.


Generator Set
Model 04725
Rated Power (kW)* 25
60 Hz Phase Single
Voltage 120/240V
Amps @ 120/240V, Single Phase 60HZ 208.3/104.2
Engine / Alternator RPM 3600
Engine 1.5L OHC 4 cyl.
Fuel Natural gas or LP gas
UL 2200 Listed Yes
CSA Listed Yes
Main Line Circuit Breaker 125 Amp
Engine Cooling Liquid
Dimensions (L" x W" x H") 68 x 30 x 40
Unit Wt. (lbs.)** 1010
* Natural gas and LP gas rating may decrease depending on btu content of local gas supply. Proper sizing of tank/piping is required to ensure full output.

** Includes Transfer Switch

Controls
Start / Stop Control Cyclic cranking: 7 seconds on, 7 seconds rest. 90 seconds overcrank protection.
Automatic Low Oil Shutdown Standard
Overspeed Shutdown Standard, 70 Hz
Overcrank Protection Standard
Automatic Voltage Regulator with Over-Voltage Protection Standard
Engine Warmup 15 seconds
Engine Cool-Down 1 minute
Safety Fuse Standard
Starter Lockout Starter cannot re-engage until 5 seconds after engine has stopped
2 Amp Timed Trickle Battery Charger Standard
Mode Switch: Auto Switch Utility failure/7 day exerciser
Auto Switch Utility failure/7 day exercise
Off Switch Stops unit. Power is removed. Control and charger still operate
Manual / Test Start with starter control, unit stays on. If utility fails, transfer to load takes place